ups.b — Battery / Charger (css610out only)

Backs the second half of the Health page on the SwOS Lite css610out build (outdoor unit with battery backup). One record; polled every 1 s.

Label Lite id Type Access Notes
PSU i0d enum: failed, ok, checking RO
Battery i11 enum: not connected, unknown, normal, low, depleted, temp. out of range RO
Battery Voltage i14 + i13 composite: uint mA @ uint 0.01 V RO current @ voltage
Time On Battery i12 uptime (seconds) RO
Cutoff Voltage i17 int, 0.01 V units (float input), 19–26 V RW
Temperature i16 int (8-bit), °C RO battery temperature sensor
Charger group
Charger i01 enum: resetting, disabled, charging, float, done, unstable power, no power, no battery, temp. out of range, overload, invalid profile, charging limited, controller error, invalid battery RO
Mode i05 enum: disabled, standby, cyclic, no float RW
Voltage Preset i04 enum: flooded, AGM, gel, LFP, custom RW selecting a preset adjusts the voltage fields
Charge Voltage i06 int, 0.01 V (float input), 23–30 V, default 29.3 RW
Float Voltage i07 int, 0.01 V (float input), 23–30 V, default 26.5 RW
Voltage Offset (−mV/°C) i08 uint ≤ 100 RW temperature compensation
Temperature Range i0a enum: 0~40C, -10~50C RW
Temperature Override i03 int (8-bit), −30…40, default −127 = off RW
Capacity (Ah) i09 uint, 1–255 RW
Current (mA) i0b uint, 200–1600 RW charge current
EoC Current i0c enum: 20mA, 0.01C, 0.02C, 0.05C, 0.1C RW end-of-charge threshold