Repository navigation
data: helium on matched measures; xenon against RMT (TC-1092 to TC-1094) - #4
Merged
Merged
Conversation
- travers_2026_pyroraptor (new, tier 3): helium with both electrons active, haCC(1), haCC(5) and one electron at 390 nm on box-converged measures (populations above n <= 4 and n <= 5), and haCC in Sato et al.'s 800 nm pulse. Corrects TC-1050: haCC's helium is 0.96 to 0.99 of the exact atom (not 0.76 to 0.81) and the atom 1.6 times one electron (not 1.7 to 1.8); Parker et al.'s rate stays confirmed. - Part N of the tRecX runs: one xenon 5p electron in Hartmann et al.'s RMT field, read as RMT's ground-state survival. RMT's atom depletes like 0.53 to 0.63 of one m = 0 electron; the default 1.5 to 2.1 times RMT (TC-1093). - hartmann_2022: the measured neutral abundance of xenon (TC-1094); the default is 0.96 to 1.13 of its depletion up to 1.6e14 W/cm2. - Validators helium_matched_ratios, xenon_rmt_ratios, xenon_survival; three manual tables. No recommended value changed. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01PiTg5xCtsHUFpsdY2EjpB5
Codecov Report✅ All modified and coverable lines are covered by tests. 📢 Thoughts on this report? Let us know! |
pyroraptor confirmed and corrected the one-shell offset in its haCC comparisons at 390 nm on 17 October 2026 (merged at 295a255b); the record, its provenance and the register entry now say so. No value changes. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01PiTg5xCtsHUFpsdY2EjpB5
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
travers_2026_pyroraptor: helium with both electrons active, haCC(1), haCC(5) and one electron at 390 nm (A2's 6 fs pulse), read as the population above the bound shells n <= 4 and n <= 5 1000 au after the pulse, which is converged in the box; and haCC in Sato et al.'s 800 nm pulse with their measure.helium_matched_ratios,xenon_rmt_ratios,xenon_survival; three generated manual tables; changelog, counts and the golden identity digests of He and Xe (text of their reasons only).No recommended value, model value or stored fit changed.
Verification
poe check: lint, types, numpydoc, codespell, reuse clean; coverage 100 %; two test-hygiene failures in the new tests (tolerance floors, the page test's table list) were fixed and those files re-run green; the docs build (poe docs) succeeds after two docstring fixes. The whole gate was not re-run after the fixes.poe test-library: 512 passed.For review
$RUN_ROOT.🤖 Generated with Claude Code
https://claude.ai/code/session_01PiTg5xCtsHUFpsdY2EjpB5