Open hardware and firmware for EITWatch: a smartwatch-back planar Electrical Impedance Tomography (EIT) system for hand gesture sensing.
Eight gold-plated disk electrodes sit in a 31 mm ring on a 40 mm × 60 mm PCB. The electrode ring fits a standard 40 mm watch case back; a 20 mm board extension holds the discrete analog front end. A Seeed XIAO ESP32 module plugs into dual 1×7 headers and sequences a multi-depth injection schedule (35 impedance channels per frame).
This release accompanies the paper:
Liu, Alam, and Ahuja. EITWatch: Smartwatch-Integrated Planar Electrical Impedance Tomography for Hand Gesture Recognition. UIST 2026.
hw/
├── README.md # this file
├── altium/ # Altium Designer project sources
├── bom/ # bill of materials
├── docs/ # overview figure, schematic PDF, STEP model
├── fabrication/gerber/ # Gerber + NC drill for PCB fab
└── firmware/ # ESP-IDF firmware (XIAO ESP32-S3)
| Path | Contents |
|---|---|
altium/ |
Editable schematic, PCB, and libraries (EITWatch.PrjPcb) |
docs/overview.png |
Prototype overview figure |
docs/schematic.pdf |
Printable schematic |
docs/eitwatch.step |
3D board model |
fabrication/gerber/ |
Fabrication outputs (copper, mask, paste, silkscreen, outline, drill) |
bom/BOM.csv |
PCB BOM (passives + ICs; MCU module and electrodes are off-board) |
firmware/ |
Acquisition firmware and host-side helper scripts |
| Item | Spec |
|---|---|
| Board size | 40 mm × 60 mm |
| Electrodes | 8 × Ø2 mm gold-plated stainless steel disks on a Ø31 mm ring (~11.9 mm adjacent spacing) |
| Sensing footprint | Fits a 40 mm watch case back; AFE occupies the remaining 20 mm |
| Excitation | AD5930 sinusoid at 50 kHz; ADA4841 V-to-I; ~1 mA peak-to-peak (AD5270-set) |
| Sensing | AD8220 instrumentation amp + AD5270 gain; AD7450 12-bit ADC |
| Switching | 4 × ADG738 8-channel matrix switches |
| Host MCU | Seeed XIAO ESP32-S3 on headers P2 / P3 (firmware in this repo targets esp32s3) |
| Frame rate | ~48 Hz for the 35-channel multi-depth schedule |
| Stackup (Gerber export) | 6 copper layers: GTL, G1–G4, GBL |
| Designator | Part | Role |
|---|---|---|
| U2 | AD5930YRUZ | Waveform generator |
| U5 | ADA4841-2YRMZ | Voltage-to-current drive |
| U4, U6 | AD5270BRMZ-100 | Digital pots (drive current / sense gain) |
| U3, U7 | AD8220ARMZ | Instrumentation amplifiers |
| U8 | AD7450BRZ | 12-bit SPI ADC |
| MUX1–MUX4 | ADG738BRUZ | Electrode matrix switches |
| U1 | TLV73325PDBVT | 2.5 V regulator |
| OS1 | ECS-2520MV-500-BL-TR | 50 MHz oscillator |
Full line items are in bom/BOM.csv. The BOM does not include the XIAO module, watch case, strap, or the eight disk electrodes (those are mechanical / off-board parts).
- Zip
fabrication/gerber/(include thedrill/folder). - Order a 6-layer board matching the Gerber stackup below (or re-export from Altium if you change the stackup).
- Suggested defaults for prototype houses (JLCPCB / PCBWay style): 1.6 mm thickness, 1 oz copper, ENIG finish on electrode pads if you plate the disks separately or solder them to pads.
- Review silkscreen and keep-out against your watch case before committing a panel.
| File | Layer |
|---|---|
main.GTL |
Top copper (Layer 1) |
main.G1 |
Inner Layer 2 |
main.G2 |
Inner Layer 3 |
main.G3 |
Inner Layer 4 |
main.G4 |
Inner Layer 5 |
main.GBL |
Bottom copper (Layer 6) |
main.GTS / main.GBS |
Top / bottom solder mask |
main.GTP / main.GBP |
Top / bottom paste |
main.GTO / main.GBO |
Top / bottom silkscreen |
main.GM |
Board outline |
drill/main-Plated.TXT |
Plated NC drill |
- Populate the mixed-signal AFE on the top side; electrodes face the skin on the bottom.
- Mount the eight Ø2 mm gold-plated stainless disks flush so the watch-back contact plane is even.
- Seat a Seeed XIAO ESP32-S3 on headers
P2/P3with the orientation matching the silkscreen. - Power and bring-up: use the firmware hardware-test path before full scanning (see
firmware/README.md).
Open altium/EITWatch.PrjPcb in Altium Designer. Main sources:
main.SchDoc– primary schematicAC_sch.SchDoc– analog / related sheetmain.PcbDoc– PCB layout*.SchLib/*.PcbLib– schematic and footprint librariesPCB.OutJob– output job used to regenerate Gerbers
Re-export Gerbers into fabrication/gerber/ after layout changes.
Firmware lives in firmware/ (ESP-IDF v5.2+). It drives the AD5930, ADG738 muxes, AD5270 pots, and AD7450 ADC, and runs the measurement / calibration application layer under FreeRTOS.
cd firmware
. $HOME/esp/esp-idf/export.sh # adjust to your IDF install
idf.py set-target esp32s3
idf.py build
idf.py -p /dev/tty.usbmodemXXXX flash monitorSee firmware/README.md for structure, flash steps, and bring-up notes. Pin macros in firmware/drivers/board_pins.h use XIAO ESP32-S3 GPIO numbers for pads D0–D10.
This is a research prototype for short-duration, IRB-approved human-subject studies or phantom / water-tank experiments. It injects a small AC current into tissue via skin electrodes.
- Do not use on people with implanted electronic devices (e.g. pacemakers) without appropriate medical / IRB review.
- Do not use as a medical device or for clinical diagnosis.
- Keep injected current and contact quality within the design envelope (~1 mA peak-to-peak at 50 kHz in the paper configuration).
- You are responsible for compliance with local electrical safety and human-subjects rules.
If you use this hardware or firmware, please cite the UIST 2026 EITWatch paper (update the BibTeX once the ACM DOI is available):
@inproceedings{eitwatch2026,
author = {Liu, Xuanyou and Alam, Novel and Ahuja, Karan},
title = {{EITWatch}: Smartwatch-Integrated Planar Electrical Impedance Tomography for Hand Gesture Recognition},
booktitle = {Proceedings of the 39th Annual ACM Symposium on User Interface Software and Technology},
series = {UIST '26},
year = {2026},
publisher = {ACM},
note = {Camera-ready; replace with ACM DOI when available}
}Copyright 2026 Xuanyou Liu, Novel Alam, and Karan Ahuja.
| Material | License | File |
|---|---|---|
Hardware (altium/, bom/, docs/, fabrication/) |
CERN-OHL-P-2.0 | LICENSE.CERN-OHL-P-2.0 |
Firmware (firmware/) |
Apache-2.0 | firmware/LICENSE |
See LICENSE for the dual-license summary.
Designed for research on planar wrist-EIT at Northwestern University. Contact: xuanyou@u.northwestern.edu.