Problem
agent/src/server.py maintains a module-global _debug_cw_failures counter, incremented under a lock on every failed CloudWatch write (:197, :226). Nothing ever reads it.
Three docstrings describe it as an operator-facing signal — :145 and :176 call it "a single alarm surface" — but there is no metric emission, no CloudWatch alarm, and no /ping or /validate exposure. The value dies with the process.
Why it matters
The counter exists to answer "is the debug/diagnostic path blind?" — i.e. is the agent failing to write the very lines an operator would use to diagnose a task. That is a genuinely useful signal on a substrate where the guest is otherwise unobservable, and it is currently unobtainable. Worse, the docstrings promise it, so a reader debugging a silent task may go looking for an alarm that does not exist.
Surfaced during the ADR-021 P2 review (PR #733, non-blocking item 6). Pre-existing, not introduced by that PR. Note that #733 removed the one place that depended on the counter rhetorically: _build_hook_log's reason #1 previously argued a build-role write would "poison the signal", and now argues from IAM namespace scoping instead. So there is no longer anything blocking a decision either way.
Options
- Expose it (smallest useful change): include it in the
/pingand/or/validateresponse body./validatealready has awarningsarray and, as of feat(compute): Lambda MicroVMs P2 — smoke parity foundations (#645) #733, logs named warnings to the build log group — the same shape would work here. - Emit it as a metric (most useful): an EMF line or a
PutMetricDatacall at task finalize, which gives operators something alarmable. Note the ordering constraint: the emitter must not itself be a CloudWatch write on the path it is measuring, and it must respect the pre-platform_configAWS-silence rule (see_aws_silent_log). - Remove it and correct the three docstrings. Legitimate if nobody wants the signal — the failures are already logged individually to stdout.
Acceptance criteria
_debug_cw_failuresis either read by something an operator can observe, or removed.- The docstrings at
server.py:145and:176describe what actually exists. - If exposed: a test asserts a non-zero counter is visible after a forced write failure, and that the exposure path does not itself perform a CloudWatch write.
- If removed: no docstring anywhere references an alarm surface.
Activity
krokoko commentedon Nov 24, 2026
Fixed in #1075, please reopen if you still face any issue, thanks !