[hardware test]: S7-1500 CPU 1511F-1 PN V2.9.7, classic S7 — pass (13/13) #909
Copy link
Copy link
Closed
Labels
hardware-testStructured result from a real PLC acceptance runStructured result from a real PLC acceptance runtest-result: passAll selected applicable real-PLC scenarios passedAll selected applicable real-PLC scenarios passed
Description
Source revision
140ccf0 (master, 2026-09-30): the revision #907 ran, so the two CPUs compare directly. #908's runner fixes are not in it.
Overall result
pass
PLC family, model, and order code
S7-1500, CPU 1511F-1 PN (a fail-safe CPU); order code not recorded (order_code_status: unavailable:AttributeError, the runner bug fixed in #908)
Firmware and security mode
V2.9.7, PUT/GET enabled for this run only, non-optimized fixture DBs (DB1 read-only, DB2 scratch). The safety program was not touched.
Host environment
Python 3.11.2 (CPython), Linux x86_64; pytest-bdd 8.1.0, python-snap7 3.2.0; dependencies from uv sync --extra test
Run time (UTC)
2026-10-01T09:40:44Z (the scratch-write run; a read-only smoke run at the same minute also passed 5/5)
Sanitized report artifacts
JSON report
{
"ended_at": "2026-10-01T09:40:45.176386+00:00",
"environment": {
"architecture": "x86_64",
"implementation": "CPython",
"os": "Linux",
"os_release": "6.1.0-53-amd64",
"pytest_bdd": "8.1.0",
"python": "3.11.2",
"python_snap7": "3.2.0"
},
"overall_result": "pass",
"plc": {
"cpu_state": "S7CpuStatusRun",
"family": "S7-1500",
"firmware": "V2.9.7",
"model": "CPU 1511F-1 PN",
"order_code": "",
"order_code_status": "unavailable:AttributeError",
"protocol_path": "classic_s7",
"rack": 0,
"security_mode": "PUT/GET, non-optimized fixture DBs",
"slot": 1,
"tia_configuration": ""
},
"scenarios": [
{
"diagnostic": null,
"duration_seconds": 0.015812239958904684,
"scenario_id": "tests/real_plc/test_acceptance.py::test_establish_and_close_a_session",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"smoke"
]
},
{
"diagnostic": null,
"duration_seconds": 0.022633926011621952,
"scenario_id": "tests/real_plc/test_acceptance.py::test_read_the_canonical_fixture",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"smoke"
]
},
{
"diagnostic": null,
"duration_seconds": 0.018758510006591678,
"scenario_id": "tests/real_plc/test_acceptance.py::test_read_multiple_values_in_one_request",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"smoke"
]
},
{
"diagnostic": null,
"duration_seconds": 0.018106958945281804,
"scenario_id": "tests/real_plc/test_acceptance.py::test_reconnect_after_a_clean_disconnect",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"smoke"
]
},
{
"diagnostic": null,
"duration_seconds": 0.02350460598245263,
"scenario_id": "tests/real_plc/test_acceptance.py::test_repeated_operations_do_not_corrupt_the_session",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"smoke"
]
},
{
"diagnostic": null,
"duration_seconds": 0.01520702603738755,
"scenario_id": "tests/real_plc/test_acceptance.py::test_roundtrip_a_value_and_restore_the_plc[INT]",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"write"
]
},
{
"diagnostic": null,
"duration_seconds": 0.014817069983109832,
"scenario_id": "tests/real_plc/test_acceptance.py::test_roundtrip_a_value_and_restore_the_plc[REAL]",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"write"
]
},
{
"diagnostic": null,
"duration_seconds": 0.016789042041637003,
"scenario_id": "tests/real_plc/test_acceptance.py::test_roundtrip_a_value_and_restore_the_plc[BYTE]",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"write"
]
},
{
"diagnostic": null,
"duration_seconds": 0.016873087035492063,
"scenario_id": "tests/real_plc/test_acceptance.py::test_roundtrip_a_value_and_restore_the_plc[WORD]",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"write"
]
},
{
"diagnostic": null,
"duration_seconds": 0.013880087994039059,
"scenario_id": "tests/real_plc/test_acceptance.py::test_roundtrip_a_value_and_restore_the_plc[DWORD]",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"write"
]
},
{
"diagnostic": null,
"duration_seconds": 0.015659189084544778,
"scenario_id": "tests/real_plc/test_acceptance.py::test_roundtrip_a_value_and_restore_the_plc[DINT]",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"write"
]
},
{
"diagnostic": null,
"duration_seconds": 0.014981463085860014,
"scenario_id": "tests/real_plc/test_acceptance.py::test_roundtrip_a_value_and_restore_the_plc[CHAR]",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"write"
]
},
{
"diagnostic": null,
"duration_seconds": 0.015706156962551177,
"scenario_id": "tests/real_plc/test_acceptance.py::test_roundtrip_a_value_and_restore_the_plc[BOOL]",
"status": "passed",
"tags": [
"classic_s7",
"real_plc",
"write"
]
}
],
"schema_version": "1.0",
"source": {
"commit": "140ccf08f7bb602b63d2fa074bdedaa5399d8431",
"dirty": false,
"kind": "git"
},
"started_at": "2026-10-01T09:40:44.797590+00:00",
"tester": "@russwing"
}
JUnit XML (the hostname attribute redacted)
<?xml version="1.0" encoding="utf-8"?><testsuites name="pytest tests"><testsuite name="pytest" errors="0" failures="0" skipped="0" tests="13" time="0.375" timestamp="2026-10-01T09:40:44.800927+00:00" hostname="redacted"><testcase classname="tests.real_plc.test_acceptance" name="test_establish_and_close_a_session" time="0.016" /><testcase classname="tests.real_plc.test_acceptance" name="test_read_the_canonical_fixture" time="0.023" /><testcase classname="tests.real_plc.test_acceptance" name="test_read_multiple_values_in_one_request" time="0.019" /><testcase classname="tests.real_plc.test_acceptance" name="test_reconnect_after_a_clean_disconnect" time="0.018" /><testcase classname="tests.real_plc.test_acceptance" name="test_repeated_operations_do_not_corrupt_the_session" time="0.024" /><testcase classname="tests.real_plc.test_acceptance" name="test_roundtrip_a_value_and_restore_the_plc[INT]" time="0.016" /><testcase classname="tests.real_plc.test_acceptance" name="test_roundtrip_a_value_and_restore_the_plc[REAL]" time="0.015" /><testcase classname="tests.real_plc.test_acceptance" name="test_roundtrip_a_value_and_restore_the_plc[BYTE]" time="0.017" /><testcase classname="tests.real_plc.test_acceptance" name="test_roundtrip_a_value_and_restore_the_plc[WORD]" time="0.017" /><testcase classname="tests.real_plc.test_acceptance" name="test_roundtrip_a_value_and_restore_the_plc[DWORD]" time="0.014" /><testcase classname="tests.real_plc.test_acceptance" name="test_roundtrip_a_value_and_restore_the_plc[DINT]" time="0.016" /><testcase classname="tests.real_plc.test_acceptance" name="test_roundtrip_a_value_and_restore_the_plc[CHAR]" time="0.015" /><testcase classname="tests.real_plc.test_acceptance" name="test_roundtrip_a_value_and_restore_the_plc[BOOL]" time="0.016" /></testsuite></testsuites>Skips, failures, and notes
- Smoke (read-only): 5/5. Scratch writes (
--allow-write, DB2 only): 8/8 types (INT, REAL, BYTE, WORD, DWORD, DINT, CHAR, BOOL), each restored and read back.--allow-adminoff. - DB2 was byte-identical afterwards (all 38 bytes compared, before and after).
- Block upload/download was not run on this CPU. The run kept to DB reads and scratch writes.
- With PUT/GET off, the same CPU refuses every classic S7 read with class=0x81, code=0x04 (30 Sep).
- Runner notes: as in [hardware test]: S7-1200 CPU 1212C V4.7.3, classic S7 — pass (13/13) #907, the JUnit XML's
hostnameattribute is redacted by hand, and the order-code read fails withAttributeError.
Safety confirmation
- I reviewed the attachments and they contain no PLC address, credentials, private keys, plant/site identifiers, or proprietary PLC program.
Reactions are currently unavailable
Metadata
Metadata
Assignees
Labels
hardware-testStructured result from a real PLC acceptance runStructured result from a real PLC acceptance runtest-result: passAll selected applicable real-PLC scenarios passedAll selected applicable real-PLC scenarios passed
Activity
gijzelaerr commentedon Oct 2, 2026
Thanks for the run, and for checking DB2 byte for byte afterwards! Having a fail-safe 1500 next to the 1212C is useful coverage.
The two runner problems you noted are both fixed in #908: the order code was read from the wrong
S7OrderCodefield, and the JUnit XML now dropshostnameand redacts addresses on its own. Once that's merged, a rerun on either CPU would give us a report with the order code filled in, if you have time. No rush; please open it as a new issue and link this one, per the result policy.docs: note S7-1200 refusing block upload with 0x81/0x04 (#911)
gijzelaerr commentedon Oct 3, 2026
#908 is merged, so a rerun on current master will record the order code and produce a clean JUnit XML without manual redaction. The PUT/GET-disabled 0x81/0x04 behaviour you saw is now in the error reference (#911).
gijzelaerr commentedon Oct 13, 2026
Recorded in the new Tested and Verified Hardware section of the PLC support matrix (#947). Thanks for the runs!