SECURITY.md

Security Policy

Reporting a Vulnerability

If you discover a security vulnerability in sunspecctl, please report it responsibly.

Do not open a public GitHub issue for security vulnerabilities.

Instead, please email security@otfabric.com, or open a private advisory on GitHub (the Security tab → Advisories → Report a vulnerability), with:

  • A description of the vulnerability
  • Steps to reproduce the issue, ideally the exact command
  • The affected version(s) (sunspecctl version output)
  • Any potential impact you've identified

We will acknowledge your report within 48 hours and aim to provide a fix or mitigation within 7 days for critical issues.

Supported Versions

Version Supported
Latest release Yes
Older releases Best effort

Security Considerations

SunSpec Modbus Has No Built-In Security

SunSpec devices are read, and with sunspecctl serve simulated, over Modbus, which carries no authentication and no encryption on TCP, UDP, RTU or ASCII: anyone who can reach a device can read and write it, and anyone on the path can read or alter the traffic.

  • Use sunspecctl only on devices and networks you own or are authorized to access
  • Keep Modbus traffic on isolated, trusted networks; never expose port 502 of an inverter, meter or battery to the Internet
  • Across untrusted networks, use Modbus over TLS (tcp+tls://, supported by go-modbus) where the device supports it, or a VPN or secured gateway

Data Read From Devices Is Untrusted Input

  • Model IDs, lengths, strings and values come from the device. Discovery is bounded and lengths are validated before decoding, but treat what sunspecctl prints as untrusted: validate ranges before using values for control decisions, and escape strings (manufacturer, model, serial number) before putting them in HTML, SQL or shell commands
  • sunspecctl output can contain serial numbers, network addresses and production figures; treat it as sensitive operational data when storing or sharing it

Reading Only, as a Client

As a client sunspecctl reads and decodes; no command writes SunSpec control points to a device. This is enforced, not only intended: detect, models, read*, poll* and capture create their Modbus client with only Read Holding Registers (0x03) and Read Input Registers (0x04) allowed (sunspec.ReadFunctionCodes() given to go-modbus's AllowedFunctionCodes). Any other function code is refused by the client, with modbus.ErrFunctionCodeNotAllowed, before anything is sent; TestClientIsReadOnly checks it against a device that counts writes.

Serving a Simulated Device

sunspecctl serve opens a Modbus TCP listener without authentication or encryption: whoever can reach it can read every register of the simulated device and write its writable points.

  • Listen on the loopback address unless others must reach it: --url tcp://127.0.0.1:1502. tcp://0.0.0.0:... and tcp://[::]:... accept connections from every network the machine is on. Never expose a served device to the Internet
  • Do not run a simulator on a production network where a controller or a monitoring system could take it for real equipment: a device file made with capture carries the manufacturer, model and serial number of the original
  • A captured device file is operational data: it can contain serial numbers, network addresses, settings and production figures. Check it before sharing or committing it
  • Device files are parsed and validated before anything is served, but only serve files you wrote or reviewed

Dependencies

make check runs govulncheck. The protocol code is in go-sunspec and go-modbus; a vulnerability there is fixed by a release that updates the dependency. Vulnerabilities reported in the Go standard library are fixed by building with a patched Go release.

Verifying Downloads

sunspecctl release archives are published with a SHA-256 checksum file. Verify the checksum before installing.