37 changes: 37 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,43 @@

## [Unreleased]

### saj-emanager 0.1.1

Emitted power uses the same signs as the other drivers. Generation is
negative. Battery power is positive when charging and negative when
discharging. Grid power is positive on import and negative on export.

The H2 wire is discharge-positive on the battery, so `0x8491` is negated
once at the boundary. The H2 grid word is already import-positive, so
`0x8496` and the phase watts are not. Inverter, load and generator words
have no stated sign and stay on `*_vendor` metrics, off the DER streams.
Still unverified on an eManager.

### saj-emanager 0.1.0

Read-only telemetry for a SAJ eManager C1 Pro in front of one or more CHS2/CH2
hybrids. Modbus TCP only, port 502. The register sheet marks RTU as not supported.

- PV, grid and battery come from the aggregate block at `0x848A`. Battery
telemetry is emitted only when capacity, SoC or battery power says a pack
is there. A failed or short read is left out; it is not reported as 0 W.
- Phase voltage and frequency are divided by `DeviceNum` only when the scaled
value cannot be one phase and the quotient can. The register sheet does not
say those registers are summed. Eniris does, and only for voltage and
frequency. Power is never divided.
- Emitted signs match the rest of the catalog. Generation is negative.
Battery power is positive when charging and negative when discharging
(the H2 wire is discharge-positive, so `0x8491` is negated). Grid power is
positive on import and negative on export (the H2 wire already is, so
`0x8496` is not negated). Word order is high word first. The eManager
sheet states none of this. All three are unverified.
- `0x8400`–`0x8405` are documented, including the ±11000 setpoint scaling and
the SEC-C map that reuses the same addresses, and are not written.
- Not run on hardware. The first site to check is Castellum Örebro.

FTW's bundled copy does not move with this commit. Bump the pin and run
`scripts/sync-bundled-drivers.sh`.

### zap 3.1.3

`read_pv` and `read_battery` read again on Zap firmware 7.x. Data model v2 calls
Expand Down
2 changes: 2 additions & 0 deletions SUPPORT_STATUS.md
Original file line number Diff line number Diff line change
Expand Up @@ -120,6 +120,8 @@ Catalog source is not proof that a target can install or run a driver.
| pixii_pv | 0.3.3 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| remne_p1ib | 0.1.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| remne_p1ib | 0.1.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| saj-emanager | 0.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| saj-emanager | 0.1.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| saj | 1.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| saj | 1.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| schneider_meter | 1.0.5 | ftw-core | not_assessed | — | not_recorded | not_assessed |
Expand Down
11 changes: 11 additions & 0 deletions devices.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -1098,6 +1098,17 @@ manufacturers:
control: false
firmware_versions: ""
notes: "Same H2-Protocol map as the three-phase hybrid. Ampere.StoragePro / EKD-Solar is a rebadged HS2. Telemetry only."
- name: "eManager C1 Pro"
variants: [eManager C1 Pro]
regions: []
protocols:
- protocol: modbus
driver: "saj-emanager"
version: "0.1.1"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
notes: "Site controller in front of 1..N CHS2/CH2 C&I hybrids. Modbus TCP only, port 502; the register sheet marks RTU as not supported. Telemetry only, decoded from the community eManager/SEC-C workbook. Not tested on hardware. First check is Castellum Örebro (3x CHS2 50 kW). Control 0x8400-0x8405 is documented and not written."
- name: "SMA"
model_families:
- name: "SMA Home Manager 2.0"
Expand Down
607 changes: 607 additions & 0 deletions drivers/lua/saj-emanager.lua

Large diffs are not rendered by default.