5 changes: 5 additions & 0 deletions .changeset/bundle-zap-312.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,5 @@
---
"ftw": patch
---

Bundle zap 3.1.2. A Sourceful Zap works as the site meter again after it updates to firmware 7.x. That firmware renamed the fields in its local API, so the driver found no power reading and FTW lost its site meter and stopped dispatching. The driver now reads both the old and the new names. `read_pv` and `read_battery` on a Zap with firmware 7.x are not covered yet.
2 changes: 1 addition & 1 deletion drivers/BUNDLED_SOURCE.json
Original file line number Diff line number Diff line change
Expand Up @@ -16,7 +16,7 @@
"from the signed channel. Run scripts/sync-bundled-drivers.sh to update."
],
"repository": "srcfl/device-drivers",
"commit": "107eb609e38eced5f88af383107733a28993554b",
"commit": "d662c3eb1910b999b2ad6aa4a1275e789c6897b3",
"source_dir": "drivers/lua",
"drivers": [
"ambibox_v2x", "ctek", "ctek_hybrid", "ctek_v2", "deye", "easee_cloud",
Expand Down
58 changes: 58 additions & 0 deletions go/internal/drivers/zap_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -364,3 +364,61 @@ func TestZapDoesNotUseUnsafeLegacyRESTControl(t *testing.T) {
t.Fatalf("read-only Zap driver made %d REST control writes, want 0", got)
}
}

// A Zap on firmware 7.x serves the local API in data model v2. These are the
// names a Zap-HAN on 7.0.3 sent: W_ac, l1_V_ac, and null for what it did not
// read. Losing them leaves FTW without a site meter.
func zapV2MeterStub(meter map[string]any) zapAPIStub {
return zapAPIStub{
devices: map[string]any{"count": 1, "devices": []any{map[string]any{
"type": "p1_uart", "device_type": "energy_meter", "sn": "p1m-v2",
"ders": []any{map[string]any{"type": "meter", "enabled": true, "location": "grid"}},
}}},
snapshots: map[string]any{"p1m-v2": map[string]any{
"meter": meter,
"version": "v2",
"format": "p1_uart",
}},
}
}

func TestZapReadsMeterOnDataModelV2(t *testing.T) {
stub := zapV2MeterStub(map[string]any{
"type": "meter", "make": "p1", "timestamp": 1793786219266, "read_time_ms": 2,
"W_ac": 2388, "Hz": nil, "apparent_VA_ac": nil, "reactive_var_ac": -114,
"total_import_Wh_ac": 8014739, "total_export_Wh_ac": 0,
"l1_V_ac": 230.1, "l1_A_ac": 8.1, "l1_W_ac": 1872,
"l2_V_ac": 231.8, "l2_A_ac": 1.9, "l2_W_ac": 451,
"l3_V_ac": 228.7, "l3_A_ac": 0.2, "l3_W_ac": 64,
})
tel, _, _ := loadZapForTest(t, stub, nil)

meter := tel.Get("sourceful-zap", telemetry.DerMeter)
if meter == nil || meter.RawW != 2388 {
t.Fatalf("meter = %+v, want 2388W import", meter)
}
data := readingData(t, meter)
for key, want := range map[string]float64{
"l1_v": 230.1, "l1_a": 8.1, "l1_w": 1872,
"l2_v": 231.8, "l2_a": 1.9, "l2_w": 451,
"l3_v": 228.7, "l3_a": 0.2, "l3_w": 64,
"total_import_wh": 8014739, "import_wh": 8014739,
"total_export_wh": 0, "export_wh": 0,
} {
if data[key] != want {
t.Fatalf("meter %s = %v, want %v (%+v)", key, data[key], want, data)
}
}
if _, ok := data["freq_hz"]; ok {
t.Fatalf("Hz null must stay unknown, got %+v", data)
}
}

func TestZapDoesNotInventZeroForNullPowerOnDataModelV2(t *testing.T) {
tel, _, _ := loadZapForTest(t, zapV2MeterStub(map[string]any{
"type": "meter", "W_ac": nil, "l1_W_ac": 100,
}), nil)
if got := tel.Get("sourceful-zap", telemetry.DerMeter); got != nil {
t.Fatalf("W_ac null must not become a synthetic zero: %+v", got)
}
}
Loading