19 changes: 19 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,25 @@

## [Unreleased]

### zap 3.1.3

`read_pv` and `read_battery` read again on Zap firmware 7.x. Data model v2 calls
the PV DER `solar`, puts power and energy on one side (`_ac` or `_dc`), and moves
the ratings to `/api/devices`, so 3.1.2 found no PV and no battery power there.

- PV and battery read on both the 1.x and the v2 names. A value v2 sends as
`null` stays unknown.
- An AC-side voltage or current is not reported as the battery's own.
- The `inverter` DER is not counted as another resource, and `ev_charger_port`
counts as a charger.

Checked through FTW's Lua host on firmware 7.0.3, against a real Zap-P1 with a
simulated Solis. Not checked against a real inverter. Without `read_pv` and
`read_battery` the driver still reads the meter and nothing else.

FTW's bundled copy does not move with this commit. Bump the pin and run
`scripts/sync-bundled-drivers.sh`.

### zap 3.1.2

The P1/HAN site meter reads again on Zap firmware serving the data model v2
Expand Down
4 changes: 2 additions & 2 deletions SUPPORT_STATUS.md
Original file line number Diff line number Diff line change
Expand Up @@ -180,8 +180,8 @@ Catalog source is not proof that a target can install or run a driver.
| victron_mqtt | 1.0.3 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| wallbox | 1.0.3 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| wallbox | 1.0.3 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| zap | 3.1.2 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| zap | 3.1.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| zap | 3.1.3 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| zap | 3.1.3 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| zaptec | 1.0.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| zaptec | 1.0.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| zaptec_cloud | 0.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
Expand Down
2 changes: 1 addition & 1 deletion devices.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -1749,7 +1749,7 @@ manufacturers:
protocols:
- protocol: http
driver: "zap"
version: "3.1.2"
version: "3.1.3"
ders: [meter, pv, battery]
control: false
firmware_versions: ""
Expand Down
102 changes: 69 additions & 33 deletions drivers/lua/zap.lua
Original file line number Diff line number Diff line change
Expand Up @@ -32,21 +32,25 @@
-- pv: -W generation
-- battery:+W charge, -W discharge
--
-- Meter schema compatibility: some Zap firmware serves the local data model
-- v2 (srcful-data-models 2.3.0, "version":"v2" in /data/json), which renames
-- every meter field with an "_ac" suffix and lowercases the L1/L2/L3 phase
-- prefix (e.g. "L1_V" -> "l1_V_ac", "W" -> "W_ac"; "Hz" is unchanged either
-- way). This driver reads both v1 and v2 field names for the meter DER; see
-- https://github.com/srcfl/device-drivers/issues/170 for the full v2 scope
-- (pv -> solar, battery, DC/AC split), which is not yet covered here.
-- Data model v2: Zap firmware 7.x serves the local API in data model v2
-- ("version":"v2" in /data/json). Older firmware uses the 1.x names. This
-- driver reads both, and a value v2 sends as null stays unknown. v2 moved:
-- meter: W -> W_ac, L1_V -> l1_V_ac, total_import_Wh -> total_import_Wh_ac
-- pv: the DER is "solar"; power and energy are on one side, _ac or _dc;
-- mppt1_V -> mppt[1].V_dc; heatsink_C -> inverter.temperature_C
-- battery: power and energy likewise; V -> V_dc, A -> A_dc;
-- SoC_nom_fract -> soc_nom_fract; heatsink_C -> temperature_C
-- ratings: from /api/devices: rated_power_W_ac on the "inverter" DER,
-- installed_power_W_dc on "solar", rated_power_W_dc and
-- capacity_Wh_dc on "battery"

DRIVER = {
host_api_min = 1,
host_api_max = 1,
id = "zap",
name = "Sourceful Zap (P1/HAN meter)",
manufacturer = "Sourceful",
version = "3.1.2",
version = "3.1.3",
protocols = { "http" },
capabilities = { "meter", "pv", "battery" },
read_only = true,
Expand All @@ -57,7 +61,7 @@ DRIVER = {
verification_status = "production",
verified_by = { "erikarenhill@fortytwo:3d" },
verified_at = "2026-07-17",
verification_notes = "P1/HAN live-hardware verified against the official Zap Local API (srcful-zap-x-firmware 96e0258). PV aggregation was live-hardware verified on the same API before the 3.0 meter-only cut; it returns as an operator opt-in. Battery payloads are contract-tested against the firmware serializers. Inverters, batteries and chargers found on Zap are not ingested unless read_pv / read_battery is set.",
verification_notes = "P1/HAN live-hardware verified against the official Zap Local API (srcful-zap-x-firmware 96e0258). PV aggregation was live-hardware verified on the same API before the 3.0 meter-only cut; it returns as an operator opt-in. Battery payloads are contract-tested against the firmware serializers. Inverters, batteries and chargers found on Zap are not ingested unless read_pv / read_battery is set. Data model v2 checked 2026-11-04 on firmware 7.0.3: the meter on a Zap-HAN with a real meter; PV and battery on a Zap-P1 with a simulated Solis, not on a real inverter.",
tested_models = { "Sourceful Zap (ESP32-C3 controller firmware)" },
connection_defaults = {
host = "zap.local",
Expand Down Expand Up @@ -98,6 +102,24 @@ local function number(v)
return n
end

local function positive(v)
local n = number(v)
if n ~= nil and n > 0 then return n end
return nil
end

-- Data model v2 sends a power or energy value on one side, _ac or _dc, and the
-- other side null. A 1.x payload has the plain name.
local function sided(raw, name)
return number(raw[name]) or number(raw[name .. "_ac"]) or number(raw[name .. "_dc"])
end

-- A battery's or a string's own voltage and current. An AC-side value is the
-- grid's, not theirs.
local function dc_side(raw, name)
return number(raw[name]) or number(raw[name .. "_dc"])
end

local function cfg_true(v)
return v == true or v == "true" or v == 1 or v == "1"
end
Expand Down Expand Up @@ -252,22 +274,29 @@ local function discover_devices()
if der.type == "meter" then
rec.meter = true
if not first_meter then first_meter = sn end
elseif der.type == "pv" then
elseif der.type == "pv" or der.type == "solar" then
if read_pv then
rec.pv = true
rec.pv_rated_w = number(der.rated_power) or number(der.installed_power) or rec.pv_rated_w
rec.pv_rated_w = number(der.rated_power) or number(der.installed_power)
or number(der.installed_power_W_dc) or rec.pv_rated_w
else
add_other(extras, seen, "PV inverter")
end
elseif der.type == "battery" then
if read_battery then
rec.battery = true
rec.battery_rated_w = number(der.rated_power) or rec.battery_rated_w
rec.battery_capacity_wh = number(der.capacity) or rec.battery_capacity_wh
rec.battery_rated_w = number(der.rated_power) or number(der.rated_power_W_dc)
or rec.battery_rated_w
rec.battery_capacity_wh = number(der.capacity) or number(der.capacity_Wh_dc)
or rec.battery_capacity_wh
else
add_other(extras, seen, "battery")
end
elseif der.type == "v2x_charger" or der.type == "ev" then
elseif der.type == "inverter" then
-- The AC stage and rating of a device already
-- listed, not a resource of its own.
rec.inverter_rated_w = positive(der.rated_power_W_ac) or rec.inverter_rated_w
elseif der.type == "v2x_charger" or der.type == "ev" or der.type == "ev_charger_port" then
add_other(extras, seen, "charger")
elseif der.type ~= nil and der.type ~= "" and der.type ~= "meter" then
add_other(extras, seen, tostring(der.type))
Expand Down Expand Up @@ -454,6 +483,11 @@ local function snapshot_map()
return out
end

local function mppt_input(pv, index)
local inputs = type(pv.mppt) == "table" and pv.mppt or {}
return type(inputs[index]) == "table" and inputs[index] or {}
end

local function emit_pv(snapshots)
local source_count = count_kind("pv")
if source_count == 0 then return end
Expand All @@ -467,14 +501,14 @@ local function emit_pv(snapshots)

for _, rec in ipairs(tracked) do
local data = snapshots[rec.sn]
local pv = data and data.pv
local pv = data and (data.pv or data.solar)
if rec.pv and type(pv) == "table" then
local rated = number(pv.rated_power_W) or rec.pv_rated_w
local rated = number(pv.rated_power_W) or rec.inverter_rated_w or rec.pv_rated_w
if rated and rated > 0 then
total_rated_w = total_rated_w + rated
any_rating = true
end
local w = sane_power(pv.W, rated)
local w = sane_power(sided(pv, "W"), rated)
if w ~= nil and w <= 0 then
total_w = total_w + w
any_power = true
Expand All @@ -485,18 +519,20 @@ local function emit_pv(snapshots)
host.log("warn", "Zap: rejected positive PV power for " .. rec.sn .. ": " .. w .. "W")
end

local generation = bounded(pv.total_generation_Wh, 0, nil)
local generation = bounded(sided(pv, "total_generation_Wh"), 0, nil)
if generation ~= nil then
total_generation_wh = total_generation_wh + generation
any_generation = true
end

local tag = source_count > 1 and ("_" .. metric_tag(rec.sn)) or ""
emit_optional_metric("pv_heatsink_c" .. tag, number(pv.heatsink_C), "°C")
emit_optional_metric("pv_mppt1_v" .. tag, number(pv.mppt1_V), "V")
emit_optional_metric("pv_mppt1_a" .. tag, number(pv.mppt1_A), "A")
emit_optional_metric("pv_mppt2_v" .. tag, number(pv.mppt2_V), "V")
emit_optional_metric("pv_mppt2_a" .. tag, number(pv.mppt2_A), "A")
local inverter = type(data.inverter) == "table" and data.inverter or {}
local mppt1, mppt2 = mppt_input(pv, 1), mppt_input(pv, 2)
emit_optional_metric("pv_heatsink_c" .. tag, number(pv.heatsink_C) or number(inverter.temperature_C), "°C")
emit_optional_metric("pv_mppt1_v" .. tag, number(pv.mppt1_V) or number(mppt1.V_dc), "V")
emit_optional_metric("pv_mppt1_a" .. tag, number(pv.mppt1_A) or number(mppt1.A_dc), "A")
emit_optional_metric("pv_mppt2_v" .. tag, number(pv.mppt2_V) or number(mppt2.V_dc), "V")
emit_optional_metric("pv_mppt2_a" .. tag, number(pv.mppt2_A) or number(mppt2.A_dc), "A")
end
end

Expand Down Expand Up @@ -544,15 +580,15 @@ local function emit_battery(snapshots)
total_rated_w = total_rated_w + rated
any_rating = true
end
local w = sane_power(battery.W, rated)
local w = sane_power(sided(battery, "W"), rated)
if w ~= nil then
total_w = total_w + w
any_power = true
end

-- Firmware SoC_nom_fract is 0-1. Identifier keeps the
-- catalog check that soc is already a fraction, not percent.
local soc_already_fract = bounded(battery.SoC_nom_fract, 0, 1)
local soc_already_fract = bounded(number(battery.SoC_nom_fract) or number(battery.soc_nom_fract), 0, 1)
local soc = soc_already_fract
if soc ~= nil then
soc_sum = soc_sum + soc
Expand All @@ -565,17 +601,17 @@ local function emit_battery(snapshots)
end
end

local charge = bounded(battery.total_charge_Wh, 0, nil)
local charge = bounded(sided(battery, "total_charge_Wh"), 0, nil)
if charge ~= nil then total_charge_wh = total_charge_wh + charge; any_charge_energy = true end
local discharge = bounded(battery.total_discharge_Wh, 0, nil)
local discharge = bounded(sided(battery, "total_discharge_Wh"), 0, nil)
if discharge ~= nil then total_discharge_wh = total_discharge_wh + discharge; any_discharge_energy = true end

local tag = source_count > 1 and ("_" .. metric_tag(rec.sn)) or ""
if source_count > 1 and w ~= nil then host.emit_metric("battery_w" .. tag, w, "W") end
if source_count > 1 and soc ~= nil then host.emit_metric("battery_soc" .. tag, soc, "fraction") end
emit_optional_metric("battery_dc_v" .. tag, number(battery.V), "V")
emit_optional_metric("battery_dc_a" .. tag, number(battery.A), "A")
emit_optional_metric("battery_temp_c" .. tag, number(battery.heatsink_C), "°C")
emit_optional_metric("battery_dc_v" .. tag, dc_side(battery, "V"), "V")
emit_optional_metric("battery_dc_a" .. tag, dc_side(battery, "A"), "A")
emit_optional_metric("battery_temp_c" .. tag, number(battery.heatsink_C) or number(battery.temperature_C), "°C")
end
end

Expand All @@ -600,9 +636,9 @@ local function emit_battery(snapshots)
if any_rating then battery_reading.rated_w = total_rated_w end

if source_count == 1 and single then
battery_reading.v = number(single.V)
battery_reading.a = number(single.A)
battery_reading.temp_c = number(single.heatsink_C)
battery_reading.v = dc_side(single, "V")
battery_reading.a = dc_side(single, "A")
battery_reading.temp_c = number(single.heatsink_C) or number(single.temperature_C)
end

host.emit("battery", battery_reading)
Expand Down
11 changes: 2 additions & 9 deletions drivers/tests/lua_harness/test_zap_meter_schema.lua
Original file line number Diff line number Diff line change
@@ -1,12 +1,5 @@
-- Exercise zap.lua's meter field reading against both the v1 and v2 Zap
-- local API field names. Run with the scenario as arg[1]: "v1" or "v2".
--
-- This file is a draft for drivers/tests/lua_harness/test_zap_meter_schema.lua
-- in srcfl/device-drivers — see pr-drafts/README.md for how this fits that
-- repo's `make test-driver ID=zap` harness. Not run against the real harness
-- yet (no local checkout with lua55/pytest); matches the structure of the
-- existing drivers/tests/lua_harness/test_esphome_dsmr_aliases.lua, which
-- solves the same kind of field-name-aliasing problem.

local scenario = arg[1]
if scenario ~= "v1" and scenario ~= "v2" then
Expand Down Expand Up @@ -50,8 +43,8 @@ end

dofile("drivers/lua/zap.lua")

if DRIVER.id ~= "zap" or DRIVER.version ~= "3.1.2" then
error("Zap identity metadata is wrong or version was not bumped")
if DRIVER.id ~= "zap" then
error("Zap identity metadata is wrong")
end
if DRIVER.host_api_min ~= 1 or DRIVER.host_api_max ~= 1 or DRIVER.read_only ~= true then
error("Zap host API or read-only metadata is wrong")
Expand Down