Skip to content

fix(zap): read PV and battery under data model v2 (3.1.3) - #209

Merged
davmoz merged 1 commit into
mainfrom
fix/zap-v2-pv-battery
Nov 4, 2026
Merged

davmoz merged 1 commit into
mainfrom
fix/zap-v2-pv-battery

Conversation

@davmoz

@davmoz davmoz commented Nov 4, 2026

Copy link
Copy Markdown
Member

Refs #170. Follows #208, which fixed the meter.

Problem

On Zap firmware 7.x, read_pv and read_battery read nothing. Data model v2 calls the PV DER solar, sends power and energy on one side (_ac or _dc), and moves the ratings to /api/devices.

The table in #170 is out of date on a few names, so this follows fw_controller/API.md and the serializer at Zap v7.0.3:

1.x 7.0.3
ders[].rated_power on battery rated_power_W_dc
ders[].capacity capacity_Wh_dc
ders[].installed_power installed_power_W_dc
solar rated_power (the inverter's rating) rated_power_W_ac on the inverter DER
pv mppt1_V, mppt1_A mppt[1].V_dc, mppt[1].A_dc
pv heatsink_C inverter.temperature_C
battery heatsink_C temperature_C

Change

  • PV and battery read on both the 1.x and the v2 names. A value v2 sends as null stays unknown.
  • An AC-side voltage or current is not reported as the battery's own.
  • The inverter DER is not counted as another resource, and ev_charger_port counts as a charger.
  • Removes draft comments and a pinned version from the test fix(zap): read the meter DER under Zap's data model v2 local API #208 added.

Tested

Zap firmware 7.0.3, through FTW's Lua host (master 22d7e6bf), GET only:

Zap Config Result
Zap-P1, simulated Solis read_pv, read_battery PV -3000 W, 150 kWh total, rated 20 kW. Battery +5000 W, SoC 0.75, 52 V, 10 A. MPPT and temperature metrics read. Meter -1100 W
Zap-P1, simulated Solis defaults Meter only, other_resources 2 (PV inverter, battery)
Zap-HAN, real meter defaults Meter reads, no regression from #208
  • make check: 5018 passed, 936 skipped.
  • test_zap_pv_battery_schema: 7 scenarios. Five fail against 3.1.2. v1 and v2_null pass on both, as they should.

Limits: the firmware and its payloads are real, but the inverter is a Modbus simulator. Not tested on a real inverter, and no Zap on 1.x firmware was available, so the 1.x path is covered by tests only.

🤖 Generated with Claude Code

Zap firmware 7.x calls the PV DER solar, sends power and energy on one side,
_ac or _dc, and moves the ratings to /api/devices. read_pv and read_battery
therefore read nothing on 7.x. The driver now reads the 1.x and the v2 names,
and a value v2 sends as null stays unknown.

An AC-side voltage or current is not reported as the battery's own. The
inverter DER is not counted as another resource.

Also removes draft comments and a pinned version from the meter schema test.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Signed-off-by: David Mozart <dmozartandraws@gmail.com>